Attach completed CMM report with manual measurements.

StepNo Doc Type Doc Name Upload By Date
undefined Drawing undefined undefined undefined
undefined Bubble undefined undefined undefined
undefined XML undefined undefined undefined
undefined MOD3 undefined undefined undefined
Image

VA Checking into this-Update EC Later Today.

Virginia Mitchell
Wed May 14 2025 17:59:54 GMT+0000 (Coordinated Universal Time)
Image

Working to figure out the best method to efficiently clean these parts. With our current tanks, we can only clean 1 part at a time. Class B requires 2 minute soak..

Derek Bodine
Fri May 09 2025 17:25:01 GMT+0000 (Coordinated Universal Time)
Image

By material stage-5/1.

Jason Newlun
Thu May 01 2025 19:29:10 GMT+0000 (Coordinated Universal Time)
Image

Cleaning threads. EC-5/1.

Jason Newlun
Wed Apr 30 2025 15:30:46 GMT+0000 (Coordinated Universal Time)
Image

Cleaning threads. After doing a sample of 16 parts the average run time is 5 minutes a part with a total of 46hrs. EC to be determined. Please advise on the priority level of these parts..

Jason Newlun
Mon Apr 28 2025 14:57:04 GMT+0000 (Coordinated Universal Time)
Image

Cleaning threads. After doing a sample of 16 parts the average run time is 5 minutes a part with a total of 46hrs. EC to be determined. .

Jason Newlun
Mon Apr 28 2025 14:52:30 GMT+0000 (Coordinated Universal Time)
Image

Cleaning threads.

Jason Newlun
Fri Apr 25 2025 17:09:29 GMT+0000 (Coordinated Universal Time)
Image

Waiting on supplies for this job to determine EC-4/17.

Jason Newlun
Thu Apr 17 2025 19:13:12 GMT+0000 (Coordinated Universal Time)
Image

New EC: 05/02 (by Emily Marshall on 04/24/25 03:50 PM) New EC: 04/24 (by Emily Marshall on 04/21/25 05:42 AM) New EC: 04/22 (by Emily Marshall on 04/17/25 07:14 AM) Assigned to Jason Newlun, EC Date: 04/17.

Emily Marshall
Sat Apr 12 2025 19:42:57 GMT+0000 (Coordinated Universal Time)
Image

borescope each thread and remove FOD using wire brush or air blast.

Phil So
Tue Apr 08 2025 16:53:35 GMT+0000 (Coordinated Universal Time)
Image

borescope each thread and remove FOD using wire brush or air blast.

Phil So
Tue Apr 08 2025 16:53:35 GMT+0000 (Coordinated Universal Time)
Image

parts are on pallets at Yia's area .

Yia Lee
Mon Apr 07 2025 16:17:24 GMT+0000 (Coordinated Universal Time)
Image

parts are on pallets at Yia's area .

Yia Lee
Mon Apr 07 2025 16:17:24 GMT+0000 (Coordinated Universal Time)
Image

Machine: Not Required <i class="fa-sharp fa-solid fa-shield-check text-success"></i> Material: Closed <i class="fa-sharp fa-solid fa-shield-check text-success"></i> Hardware: NA <i class="fa-sharp fa-solid fa-shield-check text-success"></i> Mod: Closed <i class="fa-sharp fa-solid fa-shield-check text-success"></i> Since Planned: 0 days Since Last Moved: 0 days .

System Generated Plan Status
Fri Apr 04 2025 22:41:41 GMT+0000 (Coordinated Universal Time)
Image

Source removed from PO and Yia confirmed parts are received. .

Christine Cross
Fri Apr 04 2025 22:41:22 GMT+0000 (Coordinated Universal Time)
Image

Followed up with Customer on removing Source from PO. .

Christine Cross
Wed Apr 02 2025 16:34:21 GMT+0000 (Coordinated Universal Time)
Image

New EC: 04/07 (by Christine Cross on 04/02/25 09:34 AM) Assigned to Christine Cross, EC Date: 04/01.

AJ Moore
Fri Mar 28 2025 17:46:16 GMT+0000 (Coordinated Universal Time)
Image

3/28 - Requested Customer to remove Source from PO.

Christine Cross
Fri Mar 28 2025 17:24:19 GMT+0000 (Coordinated Universal Time)
Image

-.

Emily Marshall
Thu Mar 27 2025 20:35:04 GMT+0000 (Coordinated Universal Time)
Image

Confirming cleaning w/AJ if customer wants reworked parts per drawing or if wiping the parts down is preferred. .

Emily Marshall
Thu Mar 27 2025 16:06:35 GMT+0000 (Coordinated Universal Time)
Image

Assigned to Emily Marshall, EC Date: 03/26.

Emily Marshall
Tue Mar 25 2025 16:18:44 GMT+0000 (Coordinated Universal Time)
Image

New EC: 03/27 (by Emily Marshall on 03/27/25 08:44 AM) Assigned to Emily Marshall, EC Date: 03/24.

Emily Marshall
Mon Mar 24 2025 16:47:45 GMT+0000 (Coordinated Universal Time)
Image

In review.

Emily Marshall
Mon Mar 24 2025 16:35:12 GMT+0000 (Coordinated Universal Time)
Image

Assigned to Ben Lo, EC Date: 03/21.

Ben Lo
Fri Mar 21 2025 16:54:26 GMT+0000 (Coordinated Universal Time)
Image

Planning should already have ACK and PO packet.

undefined
Fri Mar 21 2025 16:00:11 GMT+0000 (Coordinated Universal Time)
Image

Rework scope: 1) Use scope to evaluate QTY 29/part of the 4-40 threads; identify holes needing rework 2) Use dental pic or similar tool to unpack burrs and chips 3) wire brush in thread 4) air blast thread 5) wash entire part and repackage .

AJ Moore
Thu Mar 20 2025 18:26:31 GMT+0000 (Coordinated Universal Time)
Image

cleaning of threads only. Awaiting 3 pallets to arrive with these parts..

AJ Moore
Tue Mar 18 2025 16:11:05 GMT+0000 (Coordinated Universal Time)

Part History is currently not available. Check back soon!

Clocking In & Out

Q: Do I have to enter a step number?

A: Yes, if you are clocking in or out of a job you must enter a step number.

Q: How do I know the current step number?

A: Find the work order OR enter a job number and review time tickets. It should be clear what step number is current. For Workcenters not associated with the planning, i.e. New Orders, MFG Other, etc. A triple ZERO option should populate.

Q: Can I clock into two different step numbers at the same time?

A: Yes. If you are running two different operations at the same time you can click on the "select multiple" badge and then select additional operations. There is no limit.

Q: What if I need to move a job to a workcenter not available in the drop down?

A: Submit a planning change. The work order should reflect each step needed.

Q: BUT wait... The work order has a generic workcenter(i.e. INSPECT) and I need to move the job to the CMM-HEXLG1 queue.

A: Get a manger or lead to sign off on the change. **For inspection move to planned workcenter and inspector will be prompted to enter Machine.

CNC Programming

Q: How do I clock in & out for a re-post?

Option A: Click on the purple report link when prompted. Enter job number and step number. Clock in.
Option B: Go to zones --> Re-Post. Enter job number and step number. Clock in.

Clocking Out:You can not clock out without reporting a quantity. Enter last reported quantity when alerted. To force the alert enter a quantity of 1 or greater OR click "Clock out".